Starter Generator Lab
First, electricity turns the engine. Then, the engine makes electricity.
Close the starter relay to turn electrical power into engine rotation.
CONTROL MODE
Turn the GCU on. Watch it control field and LINE.
AIRCRAFT CONTROLS
POWER SOURCESBattery master
ON24 V nominal · 25.6 V open circuit (model)
+47 A · supplying the bus
Battery current, not the 28 V target, tells you charge or discharge. A lower generator contribution can leave the battery supplying the difference, using its finite reserve.
Engine
STOPPED01 Starter relay
OPENConnect battery power to the series-start winding. No generating field is needed.
Use the starter relay above to start or restart.
GCU power
OFFAfter starting, turn the GCU ON. It controls field current and the line contactor.
GCU OUTPUTS
READ ONLY02 Field current
Read-only GCU output. Field current sets generated voltage.
03 Line contactor
OPENThe gate between generator and aircraft bus. Open means zero generator output to the bus.
TRY A CHANGE
Loads & faults
Start the engine, then watch the same machine change jobs.
RESET THE LESSON
Watch the voltage recover
Last 15 seconds · bus voltageCOMPONENT ROLES
Starter, field, and line contactor
The starter relay lets electrical power in. The field sets how much voltage the spinning generator makes. The line contactor lets electrical power out.
How this simplified lab works · sources & limits
A traditional starter-generator
Each relay shows its power contacts and five winding turns around an armature rod. The rod joins the movable contact in both positions; it is a mechanical connection, not an electrical wire. A lit amber control path energizes the coil and holds the contact closed; this is separate from current through the power contact. A closed contact can carry zero current. The battery master is shown as a direct switch. Return wires are omitted. Coil current is symbolic and is not added to the load calculation. This model gives the LINE coil an illustrative 16 V pickup and 8 V holding requirement, using actual aircraft-bus voltage. Loss of holding power releases LINE even in manual mode and clears its request; it never recloses on its own. These are invented teaching values, not aircraft specifications.
During start, battery power flows through a series-start circuit and turns the engine. Once the engine is self-sustaining, it drives the same rotor in the same direction. A separate shunt field controls generated voltage. This schematic combines armature and series-start winding in the machine symbol.
Starting the engine never enables generation. In Automatic GCU mode, turn the separate GCU power control ON after start. The GCU then controls both field and LINE; those displays are read-only. GCU OFF opens LINE and removes field command, while actual excitation decays. Entering AUTO opens LINE, removes field command and leaves GCU OFF; entering manual retains the current physical outputs for direct takeover. In this lab, protection and low-speed shutdown never move the maintained pilot switch. Real systems vary: some trip a control switch, while others use an internal protection latch. Clearing a fault preserves its position but leaves outputs inhibited: cycle OFF then ON to enable again. Restart requires GCU OFF first and never enables it; exercise buttons explicitly load an online setup. In You are the GCU mode, you directly command the generating field and LINE. The simplified start sequencer and starter interlock remain active in both modes. Fuel, ignition and simplified engine acceleration are assumed. Engine shutdown removes drive and lets the rotor coast down; the master independently disconnects the battery from both bus and starter feed. This lab deliberately powers the GCU, generating field and LINE coil from the aircraft bus. The blue feed branches from a separate terminal on the aircraft bus boundary. All external leads stop at that boundary; the interior mark is only the bus symbol. Its inline switch mirrors the existing GCU ON/OFF selection. Upstream can remain live while the open switch leaves the GCU input unpowered. An existing ON selection after bus-power loss shows a closed but unpowered switch. Manual mode holds this switch closed as the supply for your direct-control substitute, without adding another control. Moving dashes show powered control operation. Decaying field after switch-off does not imply new power from the GCU. Once online, the generator can keep that bus powered with the battery master OFF. A spinning engine alone does not supply control power: if LINE opens with the battery isolated, the bus goes dead and field current decays. Connect the battery before enabling the GCU again. Residual-voltage bootstrap and auxiliary control supplies are omitted; real manufacturer wiring varies. Manual field commands also require bus power. A new GCU ON request is rejected on a dead bus. If power is lost while an existing ON request is waiting for generator voltage, that selection stays ON but unpowered; restoring bus power resumes that explicit request. Trips latch the outputs off while the pilot switch stays ON. Restoring bus power does not reset a trip. Mode changes and Engine-off reset explicitly reset the lesson with GCU OFF.
Illustrative, not an aircraft procedure
This is a generic 28 V DC model, not a C90 system or an aircraft-specific checklist. It is for understanding only, never maintenance, troubleshooting, dispatch or flight decisions. Consult the applicable approved manuals.
Voltages and currents come from a resistive circuit with a 24 V nominal battery represented by 25.6 V open-circuit voltage, 0.04 Ω battery resistance, 0.025 Ω generator resistance, and generated voltage proportional to speed × field. Battery charging is allowed. When the master is ON, battery current is (25.6 V − bus voltage) / 0.04 Ω: positive supplies the bus, negative charges. At a 25 V bus it supplies 15 A; at 25.6 V it supplies zero; at 26 V it charges at 10 A. The 28 V regulator target does not set this changeover. Connected battery terminals share the bus voltage; 25.6 V is the internal open-circuit source, not a fixed terminal reading. Battery state-of-charge, heating, magnetic saturation, current limiting, wiring protection and engine torque dynamics are not modeled.
Automatic protection uses made-up, slowed teaching settings: over 420 A for 0.18 s, over 220 A for 2 s, reverse current below −20 A for 0.3 s, over 31 V for 0.5 s, or below 20 V for 1 s. A commanded shutdown also disconnects below 65% modeled rotor speed; its normal disconnect does not latch a fault. Trips open LINE, remove the field command and latch, without moving the pilot GCU switch. Field strength decays rather than disappearing instantly. A bus short remains battery-fed after generator isolation if the battery master is ON. With both sources disconnected, the fault remains but has no supply. Turning the battery master OFF alone does not isolate a connected generator. Clearing the fault simulates removing the fault; it is not an operational reset procedure. The engine and battery-master position are preserved when clearing a fault.
Primary references
FAA Powerplant Handbook · Chapter 5, pp. 5-10–5-11 ↗Series-start and shunt-generating operation.
VR Avionics · SGC manual, pp. 10–14 ↗Manufacturer example of field regulation, voltage build-up and generator connection. This unit includes a generator-terminal bootstrap supply; that separate supply is intentionally omitted from this bus-fed teaching model.
Enstrom · Maintenance Manual, §6-63 ↗Manufacturer example of field-current regulation and protective disconnection. These sources explain principles; they do not validate this lab’s numerical settings.
Concorde Battery · Maximize Your Battery’s Life ↗Nominal battery rating and open-circuit voltage are different. This lab uses a fixed source voltage and does not model capacity, state of charge or damage.