← Back to Turbine Systems labsENGINE SYSTEMS

Nested Spool Lab

Two shafts. One axis. Each can turn at its own speed.

SIMPLIFIED TWO-SPOOL TURBOFAN · SIDE CUTAWAYSTOPPED
Independent concentric N1 and N2 shaftsThe blue inner N1 shaft connects the fan to the low-pressure turbine. The amber hollow outer N2 shaft connects the high-pressure compressor to the high-pressure turbine. A starter drives only N2. Air passes through the compressor and combustor, then the high- and low-pressure turbines. Bearings permit independent rotation.BYPASS AIRAIR INEXHAUST →FANHP COMPRESSORCOMBUSTORHP TURBINELP TURBINEICE LOCK · N1 = 0STARTERdrives N2 onlyShafts shown enlarged; no gear link between spools.
N1 · FAN + LP TURBINE0.0% reference speed
N2 · HP COMPRESSOR + HP TURBINE0.0% reference speed

Hold the starter. Watch N2 move first, then the airflow begin to turn N1.

01

Turn N2

Mechanical drive goes to the hollow outer shaft.

02

Add combustion

Hot gas drives both turbines. Hold the starter until the engine runs on its own.

03

Lock the fan

Stops the whole N1 spool. N2 can still be motored independently.

Look through the shafts

N2 · hollow outer shaftN1 · inner shaftBearings allow relative rotation

Follow the connection

LP turbine → inner shaft → fan. These parts turn together as N1.

HP turbine → hollow outer shaft → HP compressor. These parts turn together as N2.

Energy passes between spools through moving gas. Their shaft speeds are not mechanically locked together.

Model limits & sources

Conceptual, direct-drive two-spool turbofan, not a specific engine or operating procedure. Rotor motion is slowed for visibility; indicated speeds and time constants are illustrative, not performance data. N1 response during cold motoring depends on engine design and conditions; this model shows modest gas-driven rotation. Extra compressor stages, stators, seals, accessory gearing, and bearing supports are simplified.

The ice lock is an idealized fault that restrains the N1 spool without seizing N2. Airflow is reduced, not fully blocked. This lab turns fuel off and inhibits combustion whenever the lock is set. That is a teaching safeguard, not a claim about an aircraft’s protection system. Never start or operate a real engine with a seized or ice-bound fan; follow the aircraft’s approved procedures.

Structure and gas-path principles: FAA / industry turbofan training report. Starting principles: FAA Powerplant Handbook, starting systems. The small N1 motoring response is a qualitative illustration, not a verified value for any engine.