← Back to Weather & Cross-Country labs

Lapse rate & air parcels

Dry-air buoyancy, lapse rates, and atmospheric stability.

DRY AIR MODEL

Set up the experiment

01
Atmosphere presets
°C / 1,000 ft
−3 · inversion+6 · rapid cooling
Stable dry air

Positive = colder aloft. Negative = warmer aloft.
Changing the atmosphere clears existing parcels.

±°C
Same temperature12°C hotter / colder
ft
500 ft9,500 ft
s
30 s · faster600 s · slower

BEFORE YOU RELEASE

Try a displacement

Lift or lower the selected parcel by 500 ft, then let go at zero speed. Its potential temperature stays the same. Set the initial difference to 0°C to isolate atmospheric stability.

Vertical slice

Stable
00:00
Same atmosphere & parcels
No parcels releasedRelease a warm or cold parcel to start.
Fixed temperature scale: −60 to 100°C
EnvironmentParcel’s current adiabatNeutral buoyancy
ALTITUDE— ft
VERTICAL SPEED— ft/min
NET ACCELERATION— ft/s²
FOLLOW
No parcels yet

Selected parcel

Awaiting release
ALTITUDE—ft
VERTICAL SPEED—ft/min · up +
NET ACCELERATION—ft/s² · up +
Parcel—
Surroundings—
Difference—
Buoyancy—
+
Drag—
=
Net acceleration—

Forces per unit parcel mass, in ft/s². Drag always opposes motion.

Motion and acceleration are different. A parcel can keep rising while a downward net force slows it.

Mixing offNeutral level: —Relative volume: —

What the experiment is doing

02
1 / COMPARE TEMPERATURES

Warm air is less dense

Every parcel is at the same pressure as its surroundings. If it is warmer, it is less dense and buoyancy acts upward. If colder, buoyancy acts downward.

2 / LET THE PARCEL EXPAND

Rising air cools

As pressure falls, a dry parcel expands and cools. Descending parcels compress and warm. With mixing off, no heat is exchanged and potential temperature stays constant. Optional mixing relaxes its temperature toward the surroundings.

3 / WATCH THE MOMENTUM

Zero buoyancy isn’t a stop

A moving parcel can cross its neutral-buoyancy level and overshoot. With mixing off, stable air supplies a restoring force and drag produces a damped return. The temperature difference sets buoyancy; buoyancy plus drag sets acceleration.

Model, limits, and reference equations

This is an idealized, dry, one-dimensional parcel experiment. Surface temperature is 20°C and pressure is 1013.25 hPa. The environment is hydrostatic with one constant lapse rate. Altitude is relative to the model’s surface.

The dry-neutral reference is °C / 1,000 ft (g/cₚ). The temperature plot keeps a fixed −60 to 100°C horizontal scale across all settings. “Nearly neutral” means within 0.05°C / 1,000 ft of the dry-neutral rate; the label also states which side of neutral the environment is on. This display tolerance does not change the physics. With mixing off at the exact dry-neutral lapse rate, an initially warm parcel remains buoyant; “neutral” means a temperature-matched parcel has no restoring force after displacement. A perfectly matched parcel released at rest also stays still in unstable air until disturbed.

Tₑ(z) = T₀ − Lz
p(z) = p₀ [Tₑ(z)/T₀]g/(RdL)
For L = 0: p(z) = p₀ exp[−gz/(RdT₀)]

θ = Tₚ (p₀/p)Rd/cₚ
Mixing off: dθ/dt = 0
Mixing on: dθ/dt = (θₑ − θ)/τ
b = g (Tₚ/Tₑ − 1)
dv/dt = b − kv; dz/dt = v

Temperatures in equations are kelvins. Rd = 287.05 J/(kg·K), cₚ = 1004 J/(kg·K), g = 9.80665 m/s². Linear drag k = 0.006 s⁻¹ is an illustrative damping choice, not a calibrated prediction of a real thermal. Integration uses RK4 with steps no larger than 0.05 seconds.

The familiar 2.98°C / 1,000 ft parcel lapse is the dry-neutral reference. Here parcel temperature is calculated from ambient pressure and θ, rather than forced to cool at a fixed rate in every environmental profile. θ is conserved with mixing off; with mixing on, its exchange term is integrated alongside altitude and velocity.

Up to six parcels move independently and do not collide or alter the environment. Optional mixing is a simple temperature-exchange approximation at fixed parcel mass, not a resolved model of entrainment, turbulence, or fluid flow. The 30–600 s range is illustrative, not an estimate of real atmospheric mixing time. The mixing time τ is an e-folding time: at fixed altitude, 37% of an initial temperature difference remains after one τ. Faster mixing reduces temperature contrasts sooner. It is separate from momentum drag. Turning mixing off stops further exchange; it does not undo previous mixing. Neutral-buoyancy height is recalculated from the parcel’s current θ and can move as it mixes. Bubble sizes show relative volume at constant mass, with radius proportional to the cube root of volume. They represent air parcels, not literal balloons. At 0 or 10,000 ft, a parcel is held at the model boundary and its net acceleration is zero by constraint. If mixing is on, temperature exchange continues at that boundary. The model does not simulate moisture, condensation, clouds, wind, turbulence, or real-world thermal speeds. This is an educational experiment, not an operational weather forecast.