ILLUSTRATIVE SECTION COEFFICIENTScl0.00cd0.000
L/D 0 · q 0 lb/ft² Lift and drag above are pounds-force on a 1-foot-wide strip of this airfoil, with a 3.28 ft reference chord. They are not whole-wing or airplane loads.
Two models, with different limits
This is a two-dimensional, quasi-steady section experiment. Internally, L′ = ½ρV²c cₗ and D′ = ½ρV²c cᵈ use SI units and a fixed 1 m (3.28084 ft) reference chord. Outputs convert exactly to pounds-force per foot, displayed as force on a one-foot-wide strip. One knot is 1.68781 ft/s. Standard sea-level density is 0.002377 slug/ft³ (1.225 kg/m³). Density altitude in feet inverts the piecewise standard atmosphere through 47 km (154,199 ft) geopotential altitude, including the isothermal and stratospheric layers. Below about 0.117% of sea-level density, including zero, the readout says “Outside atmosphere model” rather than extrapolating it. At zero density, lift, drag, and dynamic pressure are exactly zero; the airflow and wake are hidden. Denser-than-standard sea-level air gives a negative density altitude. The low-angle clean lift slope comes from thin-airfoil theory. The stall curves, profile drag, device effects, and all numerical stall angles are invented for teaching, not measured or fitted airfoil predictions.
Smooth camber bends a parabolic mean line: y/c = 4m(x/c)(1 − x/c). Its maximum base height is m. A 12%-thick profile makes this visible. The trailing flap turns down about 75% reference chord; leading-edge droop bends the nose down about 18%. The droop is joined and unslotted, not an extending slat. Angle of attack refers to the original reference chord, even with devices deployed.
For the clean, low-angle section, cl = 2π(α + 2m), with α in radians. The synthetic curve rounds smoothly into each peak, then loses lift magnitude. Flap and droop shift the curve, alter its peak, and add drag. The positive and negative peaks differ with camber and device deployment.
Keep the limits in view
Section drag combines an invented baseline/device penalty, a cl² profile-drag penalty, and a post-stall separation penalty. This is not finite-wing induced drag. There is no span, aspect ratio, wingtip vortex, ground effect, or aircraft performance calculation. Reynolds-number, Mach-number, hysteresis, transient separation, pitching moment, and structural deformation effects are omitted.
The teal flow uses a Hess–Smith panel method on the actual deformed section: constant source panels, a shared vortex sheet, no-penetration conditions, and a trailing-edge Kutta condition. Streamlines are integrated in that solved velocity field, and particles accelerate with its local speed. Animation time is slowed uniformly for readability. An inviscid panel model assumes attached flow: it cannot predict stall, viscous drag, boundary layers, or turbulence. Starting four degrees before the illustrative lift peak, streamlines are progressively deflected away from the suction surface into an amber separated wake. Attached-flow lines and particles are excluded from that region; only illustrative recirculating streaks are shown inside it. The geometric deflection, shear layers, and wake motion are a qualitative teaching drawing, not a computed viscous or turbulent flow. The underlying inviscid field remains a reference outside the wake. No equal-transit-time assumption is used. Sharp device bends and highly loaded shapes reduce panel accuracy. The solver’s inviscid lift diagnostic is separate from the synthetic lift and drag numbers above.
Lift is perpendicular to incoming airflow; drag is parallel and downstream. The 1× arrow scale is 0.2 screen pixels per pound-force. Zoom applies the same fixed multiplier to both arrows; optional drag enlargement adds the explicitly labeled 5×, 10×, or 20× multiplier to drag alone; 10× is the default. The labels show total magnification. Length does not automatically rescale as conditions change. Clipped arrows have a broken shaft and an off-scale label; their numeric force remains accurate. Zero force has no arrow; tiny forces have genuinely tiny arrows, with no minimum length. The common drawing origin is illustrative, not a predicted centre of pressure.