Wing Spar Laboratory
Section shown to scale
Choose a design, then run the load test.
Front view of one half-wing, looking aft. Deflection is shown at ×3, with visual clipping for very large motion. The numerical readout is unscaled.
How this laboratory works & what it cannot predict
A tapered elastic beam
Airliner-style and Cessna-style are conceptual configurations, not the dimensions, loads or strength limits of specific aircraft. Fan blades, nacelle and pylon are visual details; the engine remains a point mass in the beam calculation.
24 Euler–Bernoulli beam elements model a symmetric I-section aluminum spar (E = 69 GPa, density = 2,700 kg/m³). Depth is the overall section height; width is flange width. Web thickness sets the central vertical plate; flange thickness sets the top and bottom plates. Tip/root taper scales depth and flange thickness linearly, while width and web thickness stay constant. Bending stress is |M|h/(2I), with I = [bh³ − (b−tw)(h−2tf)³]/12. The strength slider sets an illustrative allowable, not a certified material value.
Reference lift is the total lift on this half-wing at +1 g. Load factor scales lift, spar weight and suspended-engine inertia together. Positive lift arrows are above the spar; negative lift arrows are below. Strut reaction is computed from elastic compatibility. The strut is an axial spring with vertical stiffness kᵥ = kₐ sin²θ, where θ follows its undeformed attachment geometry. The strut can push and pull; horizontal motion and strut buckling are omitted. Lower-anchor drop and span attachment change both the drawing and vertical support stiffness.
Gust response, not a flutter prediction
Turbulence drives a damped, single-mode load-response approximation. The changing signed effective load is applied to the elastic beam. This produces illustrative gust-driven oscillation, not a validated transient finite-element simulation. There is no aerodynamic pitching moment or torsional degree of freedom: true aeroelastic flutter cannot be predicted here.
Failure triggers when calculated bending stress exceeds the selected allowable. The fracture, sparks and falling outer section are illustrative. No buckling, shear failure, fatigue, plasticity, fastener failure, strut buckling, skin, or load redistribution after fracture is modeled. Sustained load does not accumulate fatigue damage. Large deflections invalidate linear beam assumptions. Do not use this for aircraft design, airworthiness or flight limits.