This is a representative axial-stage teaching model, not a PT6 cutaway, performance prediction, operating limit, or maintenance reference. Station numbers 2, 3, 4, and 5 denote compressor inlet, compressor exit, turbine inlet, and turbine exit. C1R, C1S, C2R, T1N, T1R, and T2N are local teaching labels.
- Steady one-dimensional mean flow; constant air properties: cp = 1005 J/(kg·K), γ = 1.4. Fuel mass, cooling, bleed, radial variation, shocks, and off-design matching are omitted.
- Each compressor rotor receives the selected specific work. All turbine rotors share the total required extraction equally, including shaft loss; adding turbine stages reduces work per turbine rotor. Representative blade speed is 300 m/s; swirl change satisfies Euler work, w = U·ΔVθ. Axial speeds and turbine kinetic-energy change are chosen to give representative, subsonic mean absolute and blade-relative velocity triangles throughout the available 1–4 stage range.
- With losses on: rotor isentropic efficiencies are 90%, each fixed blade row loses 1% total pressure, the burner loses 4%, and the shaft transmits 98% of extracted work. These are illustrative assumptions.
- Static temperature is T = Tt − V²/(2cp). Static pressure is p = pt·(T/Tt)^[γ/(γ−1)]. Continuity uses a computed area at each station, A = ṁ/(ρVx), for 1 kg/s. The casing is a separate visual simplification: relative annulus area decreases linearly from 1.00 to 0.55 through the compressor and increases linearly from 0.70 to 1.20 through the turbine, with a small smooth transition through the burner. Within each section, A(s) = A_in + (A_out − A_in)·s, where s is axial position from 0 to 1. With a fixed illustrative hub, casing radius follows √(r_hub² + A/π). These teaching proportions do not reproduce the calculated station areas; the Continuity area readout and all plots still use the flow model.
- Heat input is adjusted to the selected turbine-inlet temperature. The graph ends at turbine exit, before an exhaust nozzle or downstream expansion. Residual exhaust pressure and heat remain. Ambient reference is 101.325 kPa. Some low-loading, many-turbine combinations cannot exhaust into that pressure; those component-only states show an explicit pressure-mismatch warning.
- Animation is slowed for inspection; it does not display real RPM. Main-view streaks follow mean axial and circumferential velocities in a projected annulus. Shaft stripes roll with the same angle as the rotor rows. The simplified outline is illustrative, not a mass-continuity fit, CFD solution, or blade-design calculation. Radial loading and the detailed three-dimensional flow remain outside the model. Plots join station states and do not resolve the detailed flow inside a blade passage.
FAA Powerplant Handbook, chapter 1 (axial compressor and turbine sections)
NASA: compressor thermodynamics · turbine thermodynamics · shaft matching · mass continuity · static / total relations