FUEL FLOW
User-set teaching flow, not aircraft performance
ANNUNCIATORS
BOOST ON indicates pump operation. CROSSFEED indicates an open valve.
From wing to engine
Tap a component to inspect, control, or fail it.
Quantity comparison
This comparison shows true modeled tank contents, including when a cockpit quantity indication has failed. Tank depletion is calculated from delivered engine flow. No in-flight tank-to-tank transfer is simulated. Source-stated ground transfer is outside this model because the extract does not establish its detailed return route.
Source reconciliation, assumptions & model boundaries
What was supplied
LOFT CE 525 CJ/CJ1 Training Manual, copyright 2009, printed FUEL 5-3 through 5-8. Seven supplied images contain six consecutive pages; page 5-5 appears twice. The last page ends at the limitations notes.
The narrative describes CJ crossfeed. The schematic labels a “Transfer Valve,” and a pump note distinguishes CJ1 transfer. This original drawing therefore illustrates functional connections; it does not claim an aircraft-specific check-valve installation or a CJ1 transfer model.
Values tied to the extract
- Source tank capacity: 3,200 lb total; 242.2 US gal per wing. The lab uses 1,600 lb per wing and does not convert density.
- Primary supply: 6–8 psi. Low-pressure switch: 4.65 psi, decreasing.
- Low-level float: 185 ±15 lb; this model uses 185 lb. The float system is separate from the quantity indication and does not automatically start boost.
- 30-micron filter; caution at 4.5 psid; bypass at 10 psid.
Explicit teaching assumptions
- Functional manifold and single-wet-boost pressure dominance, without calibrated pump curves or check-valve pressures.
- Boost pressure is shown as established, not an invented numeric operating pressure. The 7 psi primary readout is the midpoint of the stated range.
- Low-pressure automatic activation is latched until OFF to avoid feedback chatter; the extract does not specify relay hysteresis.
- NORMAL automatic causes follow the source’s throttle-out-of-cutoff assumption. ON works regardless of cutoff. OFF retains start and selected-crossfeed overrides when out of cutoff.
- 30 lb finite teaching sump (its inspector can reset collector fill from existing bulk fuel; actual priming is not modeled), 5,000 PPH replenishment capacity, six-second start and three-second starvation response are illustrative, not aircraft specifications.
- Firewall electric-valve position is retained without DC; hydraulic SOV following is an explicit user-selectable assumption. No separate hydraulic system or annunciator electrical supply is modeled. The DC toggle affects pumps and valve actuation only.
- Engine flow is user-set. Motive circulation, exact transient pressures, fuel temperature, vents, negative-G behavior, refueling, ground transfer and certified performance are not simulated.
Historical limitations in the extract are not current flight guidance. A blank minimum-start-temperature entry is left unresolved. Always use current aircraft-specific documentation.